What the values in the technical data sheets mean, explained: what each one measures, in which unit, and how to read it.

Heat

How well it insulates

m²K/W

R, thermal resistance

What it is. The extent to which the layer or assembly resists the passage of heat.

How to read it. The higher it is, the better it insulates. For a single material, R is the thickness in metres divided by λ.

At Isoflect
  • The two-layer reflective package: R = 2.09 m²K/W, measured on the Gold + 6 cm air + Multistrat assembly (Lambda-Meter EP500e, at 10 °C and 15 K).
  • The four-layer reflective package: R = 3.01 m²K/W, a value derived from INCD URBAN-INCERC test report no. 7039 / 18.10.2023.
  • Wolle P1500, 10 cm, the material alone: 0.10 m ÷ 0.038 W/mK = 2.63 m²K/W (calculated from the λ declared in the technical data sheet).
W/mK

λ, thermal conductivity

What it is. How readily the material conducts heat.

How to read it. The lower it is, the better the material insulates. λ describes the material, not the thickness: R depends on both.

At Isoflect
  • Wolle P2100: λ₁₀ = 0.035 W/mK.
  • Wolle P800 and P1500: λ₁₀ = 0.038 W/mK.
Source: Wolle technical data sheets, test according to SR EN 12667.
W/m²K

U, thermal transmittance

What it is. How much heat passes through one m² at a difference of 1 °C between interior and exterior.

How to read it. The lower it is, the better. U = 1/R.

Calculation example
  • Wolle P1500, 10 cm, the material alone: R = 2.63 m²K/W, hence U = 1 ÷ 2.63 ≈ 0.38 W/m²K.
For an actual wall or roof, U is calculated over the entire build-up, including the surface resistances and the timber or metal of the structure (SR EN ISO 6946).
kWh/m²/year

Energy saved

What it is. The energy saved in one year per m², calculated relative to an uninsulated roof.

How to read it. The higher it is, the more you save. Multiplied by the surface area, it gives the annual saving for the house.

At Isoflect
  • The two-layer reflective package: 176 kWh/m²/year.
  • The four-layer reflective package: 202 kWh/m²/year.
Calculated relative to an uninsulated roof, under Romanian climatic conditions.
Radiation

The aluminium face

between 0 and 1

Emissivity

What it is. An emissivity of 0.05 means that the aluminium face radiates only 5% of the heat that an ordinary surface would radiate, and therefore does not give off heat by radiation.

How to read it. The lower it is, the better.

At Isoflect
  • Reflectiva Gold, Silver, Multistrat, Bronze and Roof Pro: 0.05.
  • Roof Optim: 0.18, also after ageing.
Source: technical data sheets, test according to prEN 15976.
%

Reflectivity

What it is. The proportion of the radiant heat reaching the foil that is sent back.

How to read it. The higher it is, the better.

At Isoflect
  • Reflectiva Gold, Silver and Multistrat: 95–97%.
  • Roof Pro: 95–97%.
Source: the products’ technical data sheets.
Vapour, water and fire

How the membrane behaves

m

Sd, water vapour diffusion resistance

What it is. The extent to which the membrane resists the passage of vapour, expressed as an equivalent air layer thickness.

How to read it. High Sd = vapour barrier. Low Sd = diffusion membrane, which allows vapour to escape.

At Isoflect
  • Vapour barrier: Reflectiva Gold, Silver and Multistrat, Sd = 190 m; Reflectiva Bronze, Sd = 140 m.
  • Diffusion membrane: Roof Pro, Sd = 0.045 m; Roof Optim, Sd = 0.07 m.
Source: the products’ technical data sheets.
class

W1, watertightness

What it is. The highest watertightness class for membranes.

How to read it. The classes are W1, W2 and W3; W1 is the highest.

At Isoflect
  • Roof Pro and Roof Optim: W1, including after ageing.
Source: technical data sheets, test according to EN 1928 / EN 13859-1.
class

C-s2,d0, reaction to fire

What it is. The reaction-to-fire class: C means limited contribution to fire, s2 moderate smoke, d0 no flaming droplets.

How to read it. The letters range from A1 to F; the closer the letter is to A, the less the material contributes to fire. For smoke, s1 is better than s3; for droplets, d0 is the best.

At Isoflect
  • Wolle: C-s2,d0, no flaming droplets.
Source: Wolle technical data sheets, classification according to EN 13501-1.
g/m²

Mass per unit area

What it is. The weight of one square metre of product.

How to read it. It shows how much material you receive per m² and how much a roll weighs.

At Isoflect
  • Reflectiva Bronze: 125 g/m². Roof Optim: 155 g/m². Roof Pro: 230 g/m².
  • Wolle: the figure in the name is the mass per m²; for example, Wolle P1500 has 1500 g/m².
Source: technical data sheets, test according to EN 1849-2.
Thermal mass

Heat storage capacity

J/kgK

Specific heat capacity, c

What it is. The energy required by one kilogram of material to raise its temperature by 1 °C.

How to read it. The higher it is, the more heat the material stores per kilogram. It says nothing, however, about how well it insulates: that is indicated by λ and R.

kJ/m²K

Heat capacity of the layer

What it is. How much heat one m² of the layer stores when its temperature rises by 1 °C: density × c × thickness.

How to read it. Heavy, thick materials store a great deal; lightweight materials store little. Calculation examples using the values in the table:

  • Concrete, 15 cm (2 400 kg/m³): 2 400 × 1 000 × 0.15 = 360 kJ/m²K.
  • Plasterboard, 12.5 mm (900 kg/m³): 900 × 1 000 × 0.0125 ≈ 11 kJ/m²K.
hours

Time lag

What it is. The delay between the warmest moment outside and the warmest moment on the inner face of the wall or roof.

How to read it. A longer time lag shifts the heat peak towards the evening or night, when it can be removed by ventilation. It depends on the mass, the specific heat capacity and the λ of all layers, not of a single material. It is calculated according to SR EN ISO 13786.

Advantages and disadvantages

Advantages
  • In summer, thermal mass dampens and delays heat peaks.
  • The room temperature varies less over the course of the day.
  • Heat from the sun or from the heating system is stored and released gradually.
Disadvantages
  • The room is slow to heat up, particularly when it is used only occasionally, for example a holiday home.
  • After several days of heatwave, the charged mass releases heat towards the interior during the night as well, if it cannot be ventilated.
  • It does not replace insulation: in winter, heat losses are reduced by the thermal resistance R, not by mass.
  • Damp material stores more heat, but also conducts it more readily; SR EN ISO 10456 corrects λ according to moisture content.

Typical values of specific heat capacity

MaterialDensity, kg/m³c, J/kgK
Water, at 10 °C1 0004 190
OSB6501 700
Structural timber5001 600
Expanded polystyrene10–501 450
Mineral wool10–2001 030
Air1,231 008
Concrete2 4001 000
Plasterboard9001 000
Aluminium, alloys2 800880
Steel7 800450

Source: tabulated design values, EN 12524:2000, Tables 1 and 2, adopted in SR EN ISO 10456.

Reflective membranes and Wolle are lightweight materials: they have little mass per m² and therefore store little heat. Their role in the build-up is to stop the passage of heat, through R and through emissivity, not to store it.

Noise

Sound insulation

dB

The decibel

What it is. The unit in which noise level is measured. The scale is logarithmic: a reduction of 3 dB means half the sound energy, and a reduction of 10 dB means one tenth.

How to read it. For noise, fewer dB means quieter. For insulation, more dB blocked means better.

between 0 and 1

αw, sound absorption

What it is. The weighted sound absorption coefficient: the proportion of the sound striking the material that is absorbed, instead of being reflected back into the room. It is determined according to SR EN ISO 354 and SR EN ISO 11654. The approximate equivalent used in America is called NRC.

How to read it. The closer it is to 1, the more the material absorbs and the less echo there is in the room.

dB

Rw, weighted sound reduction index

What it is. How many decibels of airborne noise, for example voices or television, an entire wall or floor blocks. It is measured according to SR EN ISO 10140 and expressed according to SR EN ISO 717-1.

How to read it. The higher it is, the better. Rw applies to the entire wall: it depends on the boards, the structure, the sealing and the sound-absorbing material in the cavity.

Wolle and noise

The Wolle technical data sheet describes the fibre as sound-absorbing. Placed in the cavity of a partition wall or a lightweight floor, it absorbs part of the sound that would otherwise travel through the void.

αw and Rw values are entered on this page only from test reports.

Reference standards

SR EN ISO 6946 (R and U of building elements) · SR EN 12667 (λ) · SR EN ISO 10456 and EN 12524 (tabulated design values, specific heat capacity) · SR EN ISO 13786 (time lag) · prEN 15976 (emissivity) · EN ISO 12572 and EN 1931 (Sd) · EN 1928 and EN 13859-1 (W1) · EN 13501-1 (reaction to fire) · EN 1849-2 (mass per unit area) · SR EN ISO 354, SR EN ISO 11654 (sound absorption) · SR EN ISO 10140, SR EN ISO 717-1 (airborne sound insulation).

The product values are those given in the technical data sheets, available on the Documentation page.

Share this page